Micro-Sample

Mini Sample Human HO1  ( Heme Oxygenase 1 ) ELISA Kit (E-MSEL-H0020)

Mini Sample Human HO1  ( Heme Oxygenase 1 ) ELISA Kit - 1
  • Mini Sample Human HO1  ( Heme Oxygenase 1 ) ELISA Kit - 1
  • Mini Sample Human HO1  ( Heme Oxygenase 1 ) ELISA Kit - 2
  • Mini Sample Human HO1  ( Heme Oxygenase 1 ) ELISA Kit - 3
All Size Price Qty
96T $ 510.00
- +
48T $ 408.00
- +
24T $ 150.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 0.19 ng/mL
Detection Range 0.31-20 ng/mL
Sample Volume 25 μL
Manual Operation Time 1 h
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes HO1 in samples.No significant cross-reactivity or interference between HO1 and analogues was observed.
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Colorimetric method, ELISA, Sandwich
Assay Type Sandwich-ELISA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃
Expiration Date 12 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
ng/mL OD1 OD2 Mean OD Corrected OD
20 2.497 2.537 2.517 2.445
10 1.673 1.693 1.683 1.611
5 0.991 0.997 0.994 0.922
2.5 0.597 0.579 0.588 0.516
1.25 0.327 0.343 0.335 0.263
0.63 0.184 0.194 0.189 0.117
0.31 0.125 0.135 0.130 0.058
0 0.068 0.076 0.072 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(ng/mL) 0.950 3.060 9.840 0.890 2.780 10.760
Standard deviation 0.060 0.130 0.510 0.060 0.190 0.870
CV(%) 5.940 4.260 5.230 6.480 6.880 8.090
Recovery
The recovery of Human HO1 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 86-99 91
EDTA plasma (n=8) 87-100 94
Cell culture media (n=8) 95-107 101
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human HO1 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 90-105 98-112 98-115
Average 97 104 105
1:4 Range 91-104 97-109 98-112
Average 96 103 104
1:8 Range 88-99 93-109 100-114
Average 94 101 106
Stability
Each kit batch is subjected to accelerated stability testing and real-time stability monitoring. Sample performance is evaluated after storage at 37 °C for 10 days to assess the impact of elevated temperature on assay reliability and reagent integrity.
/ Variation range of 37°C mean
concentration / 2-8°C mean
Sample 1(n=16) 88.41-103.41
Sample 2(n=16) 104.52-113.43
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to HO1 . Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for HO1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain HO1 , biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of HO1 . You can calculate the concentration of HO1 in the samples by comparing the OD of the samples to the standard curve.
HMOX1 is a member of the heme oxygenase family.  Unlike its constitutive counterpart, it is an inducible enzyme triggered by external stimuli such as nitric oxide, growth factors, heavy metals, UV radiation, phorbol esters, inflammatory cytokines, heme, etc.  Transcription of HMOX1 in tissue has been shown to be a product of the nrf2/ARE pathway where an increase in its protein levels results in heme degradation.  The tissue protective effects of HMOX1 are a result of the bioactive products produced after heme degradation: iron ions, carbon monoxide, and biliverdin which is converted to bilirubin via biliverdin reductase.
Gene Alias HMOX1
Gene ID 3162
Uniport ID P09601
Protein Alias HMOX1
Research Area Cell Biology
Mini Sample Human HO1  ( Heme Oxygenase 1 ) ELISA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

Species

{{relatedElisaPage.numTotal}} Results

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定